A randomised, crossover, clinical study to assess nicotine pharmacokinetics and subjective effects of the BIDI® stick ENDS compared with combustible cigarettes and a comparator ENDS in adult smokers

Abstract

Background

Nicotine pharmacokinetic assessments of electronic nicotine delivery systems (ENDS) are crucial to understand their ability to provide an alternative to cigarette smoking. Subjective effects data also strongly contribute to this understanding. The BIDI® Stick is a disposable ENDS product which contains 59 mg/ml nicotine benzoate salt and various flavours.

Methods

In this study, we assessed nicotine pharmacokinetics and subjective effects of 6 flavour variants of BIDI® Stick ENDS in adult smokers, compared to cigarettes and a comparator ENDS product. During each of eight study visits, 18 volunteer smoker subjects randomly used one of either their usual brand (UB) of cigarette, a BIDI® Stick ENDS, or a comparator ENDS (JUUL 59 mg/ml nicotine with Virginia Tobacco flavour), during both controlled (10 puffs, 30 s apart) and ad libitum (60 min) puffing sessions. Blood samples were collected at various time points and subjective effects questionnaires were administered.

Results

Mean [SD] plasma nicotine Cmax 0–120 was not significantly different between BIDI® Stick ENDS with any flavour (range 15.3 [9.90] ng/ml for BIDI® Stick Winter to 17.6 [9.00] ng/ml for BIDI® Stick Classic) and UB cigarettes (16.2 [9.17] ng/ml). Mean [SD] AUC0-120 (range 569.7 [327.29] to 628.6 [408.99]  min*ng/ml for BIDI® Stick ENDS and 747.1 [325.48]  min*ng/ml for UB cigarettes) and median Tmax 0–120 (range 5-7 min for all BIDI® Stick ENDS and UB cigarettes) values were also not significantly different between BIDI® Stick ENDS and UB cigarettes, while subjective effects measures were also similar between BIDI® Stick ENDS and UB cigarettes. Mean [SD] plasma nicotine Cmax 0–120, AUC0-120, and median Tmax 0–120 were 6.8 [4.13] ng/ml, 243.6 [179.04] min*ng/ml, and 5 min, respectively, for JUUL ENDS. These values were significantly different compared with those for all BIDI® Stick ENDS and UB cigarettes for both Cmax 0–120 and AUC0-120 but not for Tmax 0–120.

Conclusions

BIDI® Stick ENDS delivered nicotine to users comparably to their UB combustible cigarette and higher than JUUL ENDS, and also elicited similar subjective effects such as satisfaction and relief. Thus, the BIDI® Stick ENDS may be a satisfying alternative to cigarettes among current smokers and may support their transitioning away from cigarette smoking.

Trial registration

ClinicalTrials.gov (identifier number NCT05072925).

Background

Cigarette smoking is the leading preventable cause of morbidity and mortality worldwide and is the primary causative factor in the deaths of more than 7 million smokers annually [1]. A number of serious human diseases are caused by cigarette smoking, including heart disease, lung disease, and lung cancer, which arise due to a smokers’ inhalation of toxic chemicals formed during the combustion of tobacco [2,3,4]. Cigarette smoke contains approximately 6,500 identified chemicals [3] and a number of these chemicals have a demonstrated association with the development of specific smoking-related diseases [5]. For smokers, the best possible means of reducing the risk to their health is to quit smoking [6] and large numbers of adult smokers report such a desire to stop smoking. However, the addictive nature of cigarette smoking means that quitting smoking is inherently difficult. Unfortunately, less than 10% of adult smokers actually manage to stop smoking annually [7].

Forms of nicotine delivery that satisfy a smokers’ desire for nicotine and reduce or eliminate exposure to tar and harmful toxicants found in cigarette smoke have been suggested since the 1970s as a means to reduce smoking-related health risks [8]. Regarding smokers who are either unable or unwilling to quit smoking, a number of public health bodies such as Public Health England, the UK Royal College of Physicians, the New Zealand Ministry of Health and Health Canada, have proposed that reduced-exposure products may provide a less harmful alternative to combustible cigarettes and support efforts to reduce the global burden of cigarette smoking [9,10,11]. E-cigarettes are a form of electronic nicotine delivery systems (ENDS) which generate an aerosol via electrical heating of an e-liquid that most commonly contains nicotine [12, 13]. Since the heating temperature required to aerosolise e-liquids is much lower than the smoke-producing temperature developed during the combustion of tobacco leaves in conventional cigarettes, ENDS aerosols contain far fewer and substantially lower levels of harmful toxicants compared with cigarette smoke [14,15,16]. Therefore, exposure to cigarette smoke toxicants is either greatly reduced or absent in smokers who completely switch to ENDS [17,18,19,20,21,22]. In many instances, biomarkers of exposure are at levels seen with smoking abstinence [17, 19] or in non-smokers. This exposure reduction has the potential to reduce the risk of tobacco-related disease in smokers who completely switch to using ENDS. Consequently, some public health bodies, including Public Health England, have proposed the use of ENDS as a potentially reduced-harm alternative to cigarette smoking for adult smokers [9], and particularly those who have been unable to quit by other means. Furthermore, a growing body of the literature indicates that ENDS have the potential to support smoking cessation [23], particularly in those who use ENDS daily and non-intermittently [24, 25].

It has been suggested that nicotine delivery from ENDS is an important factor in determining their ability to facilitate smokers’ switching away from cigarette smoking [26,27,28]. Nicotine-containing smoking cessation products such as nicotine gum that have higher nicotine content (e.g. 4 mg gum compared with 2 mg gum) deliver greater amounts of nicotine to users, produce greater satisfying and reinforcing effects, and are more effective in promoting smoking cessation [26, 29,30,31] particularly among highly dependent smokers [26, 32, 33]. For ENDS,  greater nicotine delivery is associated with greater reductions in urges to smoke as well as other beneficial subjective effects such as greater satisfaction, liking and reductions in withdrawal symptoms, and greater reductions in exposure to cigarette smoketoxicants [34,35,36].

The BIDI® Stick is a disposable ENDS that contains an e-liquid with 59 mg/ml nicotine in the form of a nicotine benzoate salt and a variety of flavours, which has been marketed in the USA as an alternative to cigarette smoking for adult smokers since 2014. While the nicotine pharmacokinetic profile of various types of ENDS products has been reported in the literature [13, 37, 38], including disposable ENDS [39], no studies have yet examined nicotine pharmacokinetics for disposable ENDS with a high concentration of nicotine salt in the e-liquid. In this paper, we describe findings from a clinical study assessing nicotine pharmacokinetics and subjective effects of the BIDI® Stick ENDS with various flavours, compared to combustible cigarettes and a comparator pod-based (JUUL) ENDS.

Methods

This study was an open-label, randomised, crossover, clinical study in which healthy adult smokers were assigned to use one of eight investigational products at each clinic visit and according to a pre-determined randomisation schedule. The study was conducted in July and August 2021 at the facilities of MTZ Clinical Research Sp. z.o.o., Warsaw, Poland, in accordance with the principles of International Conference on Harmonisation Harmonised Tripartite Guideline for Good Clinical Practice (GCP) and the Declaration of Helsinki. GCP compliance was assured by both a pre-study GCP audit by an independent auditor and by frequent monitoring visits during study conduct by an independent Clinical Research Associate. Ethics approval was received from the Ethics Committee of the District Medical Board in Warsaw (Resolution 15/21, 29 April 2021). All subjects received financial remuneration for their participation in the study, which was approved by the ethics committee. The study was registered on the ClinicalTrials.gov repository (identifier number NCT05072925).

Subjects

Subjects were adults aged 21–65 years inclusive and were current smokers of at least 10 factory-manufactured cigarettes a day with a Federal Trade Commission tar yield of 8-10 mg, had been smoking cigarettes for at least 12 months, and may have been dual users of ENDS. At a screening visit, which took place no more than 28 days before the first study visit, potential subjects provided written consent on an ethics committee-approved informed consent form. At this visit, a review of the potential subjects’ medical history, a physical examination, clinical laboratory assessments, an electrocardiogram (ECG), vital signs measurements, a urine pregnancy test (female subjects only), and a chest X-ray were performed to ensure that potential subjects were healthy. Urinary cotinine (≥ 200 ng/mL) and exhaled carbon monoxide (eCO; > 10 ppm) were also assessed to confirm cigarette smoking status, and a urine screen for drugs of abuse was performed. Subjects’ cigarette smoking and nicotine product use history was captured, and the Fagerström Test for Cigarette Dependence (FTCD) [40] was administered.

Female subjects were ineligible if they were pregnant or breastfeeding and were required to practice a reliable method of contraception for the duration of the study. Exclusion criteria also included any clinically relevant medical or psychiatric disorder, abnormal findings in the physical examination, clinical laboratory assessments, ECG or chest X-ray, or a positive screen for drugs of abuse. Potential subjects who had a positive text for SARS-CoV-2 (COVID-19) or displayed any symptoms indicative of active SARS-CoV-2 infection were also excluded from the study.

Study products

The BIDI® Stick is a completely self-contained disposable, non-rechargeable ENDS device (see Additional file 1: Figure S1) containing 1.4 ml of e-liquid with a 6% w/v nicotine concentration (i.e. 59 mg/ml). Similar to other ENDS e-liquids, the BIDI® Stick e-liquid also contains propylene glycol (25–35% w/v), vegetable glycerol (26–38% w/v), benzoic acid (7.2% w/v), and flavours. The device power source is a lithium-ion rechargeable battery cell with a capacity of 280mAh which is sufficient to last until the e-liquid in each BIDI® Stick is completely consumed.

Six BIDI® Stick ENDS, each containing 59 mg/ml nicotine benzoate salt and different flavours, were assessed in the study. The specific products assessed, and the flavour types for each variant, were BIDI® Stick Arctic (mint and menthol), Classic (tobacco), Zest (melon, pineapple and banana), Regal (dragonfruit and strawberry), Winter (watermelon, melon, and menthol), and Solar (strawberry and blueberry). A comparator ENDS product, the JUUL pod system ENDS with 59 mg/ml nicotine benzoate salt and Virginia Tobacco flavour, was also assessed. All subjects provided their usual brand (UB) of combustible cigarette for use as a reference cigarette.

Randomisation procedure

Randomisation sequences were prepared by MTZ Clinical Research Sp. z.o.o. and were produced using a block randomisation (Williams) procedure (18 subjects randomised to the 14 treatment sequences, size of block equal to 1) for 7 treatments in 7 periods (i.e. generation of a Latin-square design, where every treatment followed every other treatment the same number of times). Equal allocation of subjects to each sequence was ensured.

Study procedures

At screening, subjects underwent numerous assessments outlined above to assure their health status. Subjects who passed all screening assessments and provided written informed consent visited the clinic site on eight separate occasions, with each clinic visit separated by at least two days. At the first of these visits, subjects underwent nicotine pharmacokinetic and subjective effects assessments with their usual brand (UB) of combustible cigarette. Prior to each subsequent visit, subjects were provided with a supply of either the BIDI® Stick ENDS or the JUUL ENDS they were to use at their next clinic visit according to the randomisation schedule, to use at home for a familiarisation period of at least two days. At each clinic visit, subjects used their randomly assigned product and underwent nicotine pharmacokinetic and subjective effects assessments. Prior to each clinic visit, subjects were instructed to abstain from the use of any nicotine-containing products for a period of at least 12 h. Compliance with this instruction was assessed by measuring eCO with a cut-off level of < 15 ppm [26, 41, 42]. After the final clinic visit, subjects were discharged from the clinic after all nicotine pharmacokinetic and subjective effects assessments were completed. Subjects were contacted by telephone no longer than one week after the final study visit to capture any post-study adverse events (AEs).

Nicotine pharmacokinetics

During the first clinic visit (Visit 2), subjects smoked their UB combustible cigarette during two use sessions. In the first session, subjects smoked a single combustible cigarette by taking 10 puffs with each puff 30 s apart (controlled puffing). Blood samples (4 mL) were obtained for plasma nicotine analysis at -5, 3, 5, 7, 10, 15, 30, 45, 60, 75, and 120 min relative to the first puff on the cigarette. In the second session, which began immediately after the last (120 min) blood draw, subjects were allowed to take ad libitum puffs on their UB cigarette for a period of 60 min. During this ad libitum session, subjects were allowed to smoke as many cigarettes as they liked. A blood sample for nicotine pharmacokinetic analysis was drawn at the end of the session (i.e. at 180 min). At subsequent visits, subjects used their assigned ENDS product following the same procedures.

Blood samples (4 ml) for plasma nicotine analysis were drawn into dipotassium ethylenediaminetetraacetic acid (K2 EDTA) vacutainer tubes via an intravenous catheter port. No later than 90 min after collection, samples were centrifuged at 1500 RPM at 4 °C for 10 min. The plasma fraction was transferred to two sterile polypropylene screw cap tubes and stored frozen at − 20 °C within 120 min of collection. Plasma samples were shipped on dry ice to a commercial bioanalytical laboratory (Altasciences Company Inc., Laval, Quebec, Canada). Nicotine levels were assessed with a validated reversed-phase HPLC with MS/MS method, using an AB Sciex API 5000 quadrupole mass spectrometer and a Turbo V ion source with ES probe and operating in positive ion mode. The lower limit of quantification (LLOQ) for this assay was 0.200 ng/ml, and the upper limit of quantification (ULOQ) was 100.000 ng/ml.

Mass loss

The BIDI® Stick and JUUL ENDS were weighed before and after both the controlled and ad libitum use sessions. Mass loss was then calculated by subtracting the mass post-use from the mass pre-use.

Subjective effects assessments

At the end of the ad libitum puffing session, subjects completed the 21-item Product Evaluation Scale (PES) [43] for which responses were recorded on a 7-point Likert scale ranging from “Not at all” to “Extremely”.

Statistical analyses

Since this study was the first to examine nicotine pharmacokinetics in subjects using BIDI® Stick ENDS, no formal power calculations were performed. The sample size is typical of other studies reported in the literature examining the pharmacokinetics and subjective effects of different tobacco/nicotine products [37], and a sample size of 18 subjects was determined adequate to meet the study objectives.

Descriptive statistics for pharmacokinetic parameters, including baseline-adjusted maximum plasma nicotine concentration between 0 and 120 min (Cmax 0–120); time to maximum plasma nicotine concentration following controlled puffing (Tmax 0–120); and baseline-adjusted area under the plasma nicotine concentration–time curve at 120 min (AUC0-120), were summarised for each study product. AUC0-120 was calculated using a linear trapezoidal method. Following baseline adjustment, if any component of the AUC0-120 fell below zero, that component was excluded from the overall AUC value.

For inferential statistical analyses, linear mixed models were used to test differences in log-transformed Cmax 0–120 and AUC0-120 values between BIDI® Stick ENDS, JUUL, and UB cigarettes. Subject was included as a random effect. The sequence of product used was initially specified as a random effect, but the models produced non-positive definite G matrices and so this variable was removed as a random effect. Model parameter estimates were exponentiated back to their original scale and used to create 90% confidence intervals for the ratio of geometric, least-squares means. Statistically significant differences between test products were determined if the 90% confidence interval range did not include the value 1.00. Proportional odds generalised linear mixed models were used to test differences in Tmax values between BIDI® Stick ENDS, JUUL, and UB cigarettes. The subject and sequence order of the product used were specified as random effects. Statistical significance was determined for 90% odds ratio confidence intervals that did not contain the value 1.00.

The PES was analysed by assessing four composite subscales: (1) “satisfaction”; (2) “psychological reward”; (3) “aversion”; and (4) “relief” [43]. PES subscale scores were summarised using descriptive statistics for each study product, and post hoc pairwise comparisons between study products were made using linear mixed effects models with the subject specified as a random effect.

Statistical analyses were performed using SAS Version 9.4 (Cary, NC, USA) with alpha = 0.05 (2-tailed).

Safety assessments

Safety and tolerability were assessed by collecting information concerning the incidence, nature, and severity of any AEs experienced by subjects. Vital signs (blood pressure and heart rate) were also routinely monitored during study visits.

Results

Study population

Of 41 subjects who were screened, 18 (43.9%) met all of the inclusion criteria and none of the exclusion criteria and were enrolled into the study. Seventeen subjects attended the clinical site for all eight study visits and used their randomly assigned study product in the product use sessions; one subject was discontinued after Visit 2 (see later section on safety assessments). Brief demographic details of the 18 subjects are provided in Additional file 1: Table S1. Subjects’ mean [SD] age was 39.2 [9.21] years, approximately two-thirds were male, and all were of Caucasian race. On average, subjects FTCD score was 5.8 [1.66] and subjects usually smoked on average 16.6 [4.82] cigarettes per day and had been smoking for an average of 19.3 [7.66] years. Two subjects had prior experience of ENDS use, but neither these nor any other subjects were currently using ENDS.

Nicotine pharmacokinetics

During use of all study products in the controlled puffing session,plasma nicotine levels rose rapidly (Fig. 1). The mean [SD] maximum plasma nicotine concentration reached following this session (Cmax 0–120) was 16.2 [9.17] ng/ml for subjects’ UB combustible cigarette (Table 1). Cmax 0–120 values were not significantly different (Tables 1 and 2) for each of the BIDI® Stick ENDS assessed compared both with each other and with UB cigarettes and ranged from 15.3 [9.90] ng/ml for BIDI® Stick Winter to 17.6 [9.00] ng/ml for BIDI® Stick Classic. Cmax 0–120 for the comparator ENDS product (JUUL Virginia Tobacco) was 6.8 [4.13] ng/ml, which was significantly lower than that for either UB cigarettes or any of the BIDI® Stick ENDS (Table 2). Similar to Cmax 0–120, area under the plasma nicotine concentration–time curve between 0 and 120 min (AUC0-120) values for any of the BIDI® Stick ENDS were not significantly different than that for UB cigarettes, while AUC0-120 for the comparator (JUUL) ENDS product was significantly lower than that for both UB cigarettes and any of the BIDI® Stick ENDS (Tables 1 and 2). Mean time to maximum plasma nicotine concentration values for the controlled puffing session (Tmax 0–120) ranged from 6.0 min for both the BIDI® Stick Regal and Winter ENDS (SDs 1.58 and 1.41, respectively) to 6.8 [2.51] min for BIDI® Stick Zest (Table 1). Mean Tmax 0–120 for the JUUL ENDS was 5.9 [1.73] min. There were no statistically significant differences in Tmax 0–120 between any of the study products.

Fig. 1
figure 1

Meanbaseline-adjusted plasma nicotine concentration by time. N = 17–18 in each case. Solid black bars below the plot indicate the controlled (0–5 min) and ad libitum (120–180 min) puffing sessions. Errors bars have been omitted for clarity; for variability estimates, refer to Table 1. UB, usual brand; VT, Virginia Tobacco

Table 1 Nicotine pharmacokinetic parameters for BIDI stick® ENDS and comparator products
Table 2 Statistical comparison of nicotine pharmacokinetic parameters

During the ad libitum use session, plasma nicotine levels rose again for all study products (Fig. 1). While no formal statistical analysis was performed, Cmax 120–180 was highest for BIDI® Stick Arctic ENDS and lowest for UB cigarettes and JUUL ENDS (Fig. 1 and Table 1).

Mass loss

Mean [SD] mass loss from the BIDI® Stick ENDS during the controlled use sessions (Additional file 1: Table S2) ranged from 0.029 [0.0158] g (BIDI® Stick Arctic) to 0.084 [0.2124] g (BIDI Stick Regal). Mass loss from the JUUL ENDS during the controlled use session was 0.010 [0.0063] g. Mass loss from the BIDI® Stick ENDS during the ad libitum use sessions (Additional file 1: Table S2) ranged from 0.120 [0.0560] g (BIDI® Stick Regal) to 0.146 [0.0776] g (BIDI Stick Arctic). Mass loss from the JUUL ENDS during the ad libitum use session was 0.083 [0.0728] g.

Subjective effects

Analysis of the composite scores for the PES “relief”, “satisfaction”, and “aversion” subscales showed no statistically significant differences between any of the study products (Table 3). For the “psychological reward” subscale, no significant differences between UB cigarettes and BIDI® Stick ENDS were observed for 5 of the flavour variants assessed, while for BIDI® Stick Winter ENDS “psychological reward” was significantly lower (mean [SD] 3.53 [1.43]) than for UB cigarettes (4.45 [1.12]). The individual item “was it enough nicotine” item, which is a component of the “relief” subscale, was assessed individually. Mean score for this item was highest for the UB cigarette and lowest for JUUL Virginia Tobacco ENDS (Table 3). UB cigarette was significantly higher than BIDI® Stick Arctic and JUUL Virginia Tobacco, while the JUUL ENDS was significantly lower than BIDI® Stick Regal, Solar, and Zest.

Table 3 Product evaluation scale scores

Safety assessments

No serious adverse events occurred during the study. A small number of adverse events occurred in some subjects, including headaches, dizziness, and events related to blood draws (e.g. bruising). These were all classed as either mild or moderate and quickly resolved without treatment. One subject withdrew from the study following their experiencing a number of adverse events (headache, nausea, decreased appetite, coughing) after the nicotine pharmacokinetic session at Visit 2 (UB cigarette smoking).

Discussion

The primary finding from this clinical study was that the BIDI® Stick ENDS delivered nicotine to users in a manner comparable to that from subject’s UB combustible cigarette. In terms of Cmax, AUC and Tmax, these parameters were not significantly different for any flavour of BIDI® Stick ENDS compared to the combustible cigarette. Such a finding is unique in the literature for a disposable e-cigarette, although refillable tank-type ENDS devices and pod-based e-cigarettes have been found to deliver nicotine in a manner similar to [12, 13, 27, 28] or exceeding [44] that from combustible cigarettes. It has been proposed that providing sufficient nicotine delivery with either a greatly reduced, or absence of, exposure to harmful toxicants would be tolerated by smokers and thus may better serve tobacco harm reduction efforts by shifting smokers down the continuum of risk towards a less harmful tobacco product [8, 10] or helping them to stop smoking [27]. Furthermore, it has been acknowledged by the U.S. Food and Drug Administration that cigarette-like nicotine delivery from the heated tobacco product IQOS is potentially beneficial to smokers trying to switch since they are more likely to completely switch away from and not resume combustible cigarette smoking [10, 45], while a recent study concluded that an ENDS was most likely to help smokers reduce toxicant exposure and cigarette consumption when it was capable of delivering nicotine at levels similar to that of a cigarette [35]. In addition, it was proposed following a comparison of the nicotine delivery between US and European versions of the JUUL ENDS which differed in their e-liquid nicotine concentrations (59 mg/ml in the US version and 18 mg/ml in the European version) that nicotine delivery from the European version was not as effective and this may limit its potential in helping smokers stop smoking [28]. Effective nicotine delivery from non-inhaled smoking cessation products is also suggested to provide better assistance in smoking cessation [26, 30,31,32,33]. Overall therefore, our findings support that disposable e-cigarettes can, if consideration is given to product characteristics such as e-liquid nicotine concentration, inclusion of a protonating acid and providing sufficient power to the coil to generate aerosol, generate efficient nicotine delivery comparable to that from combustible cigarettes. These products may then be able to displace cigarette smoking and facilitate smokers switching to a form of nicotine intake with reduced exposure to harmful toxicants.

It has been suggested that high nicotine delivery from ENDS may be harmful if it leads to greater dependence [44], although a recent study [46] reported no differences in dependence between users of low, medium, and high strength nicotine e-liquids in either pod-based or disposable ENDS which presumably give rise to different nicotine exposures. Furthermore, from our nicotine pharmacokinetic and subjective effects findings it is unlikely that dependence on BIDI® Stick ENDS would be greater than that of combustible cigarettes, and this is supported by the literature which suggests lower dependence on ENDS compared to cigarettes [47], although that analysis did not take e-liquid nicotine concentration into account and likely arose from an analysis of users of a diverse range of nicotine concentrations. A recent study also examined dependence among smokers who switched to using the JUUL ENDS, demonstrating no difference in dependence in users of either the 35 mg/ml or the 59 mg/ml nicotine concentrations, as well as demonstrating that regardless of nicotine concentration used, dependence on JUUL use was lower than dependence on cigarette smoking [48]. While it is unlikely therefore that dependence on using BIDI® Stick ENDS would be higher than dependence on cigarette smoking, and may in fact be lower, this requires further assessment.

An interesting facet of our analyses of pharmacokinetic data is the finding of no difference in nicotine pharmacokinetics between different ENDS flavours. A small number of studies have assessed the impact of ENDS flavours on nicotine pharmacokinetics; one study reported an impact of flavours on Cmax although the data appeared skewed by an abnormally high Cmax for a cherry flavour which was likely due to the cherry e-liquid having a lower pH than the other liquids and much smaller differences were seen between other flavours with a similar pH [49], a small impact of certain flavours [49,50,51], or no impact [52, 53]. Our study data show that a comprehensive range of flavours, including mint/menthol and fruit flavours, did not differentially impact nicotine pharmacokinetics or abuse liability/dependence measures when compared to tobacco flavours.

In addition to comparable nicotine delivery to cigarettes, we observed comparable subjective effects following the use of BIDI® Sticks ENDS. Plasma nicotine Cmax in ENDS users correlates with satisfaction [34], while other subjective effects related to ENDS use are also indicators of the potential for ENDS to act as a viable alternative to cigarette smoking [54, 55]. This is likely of great importance when considering the harm reduction potential of ENDS. In this regard, a multidimensional framework for nicotine-containing products has been developed [54] which takes into account toxicity/harmfulness, appeal, and dependence. Using this framework, it has been suggested that the “sweet spot” for a nicotine product occurs when appeal and dependence are maximised and toxicity and harmfulness are minimised. Several studies have demonstrated reduced toxicant levels in ENDS emissions compared to cigarette smoke [9, 14,15,16]. In line with these findings, emissions testing of BIDI® Stick ENDS demonstrated toxicant levels which were significantly less than those in cigarette smoke (unpublished data; see Additional file 1: Table S3). This supports a profile of lower toxicity and potential for inducing harm compared with cigarette smoking. Given this potential lower toxicity, along with evidence of comparable abuse liability/dependence potential (based on nicotine delivery and subjective effects) and comparable appeal (based on subjective effects findings), this suggests that the BIDI® Stick ENDS have an appropriate balance of toxicity, appeal, and dependence and are a viable alternative to cigarette smoking which will likely have a positive impact on net population health [54].

Interpretation of the findings from this study may be subject to some limitations. Firstly, the study was conducted in a cohort of smokers in Poland, whereas BIDI® Stick ENDS are currently only marketed in the USA. Thus, our nicotine pharmacokinetic and subjective effects data may not reflect those of a US smoker switching to using the study ENDS. However, this limitation is mitigated by the study inclusion criteria, which ensured that only smokers of high-yield cigarettes were eligible for entry into the study, an approach taken to more closely match the higher yield cigarettes more commonly smoked by US smokers [56, 57]. Furthermore, in the study a comparator ENDS (JUUL Virginia Tobacco) was included and our nicotine pharmacokinetic findings for both combustible cigarettes and JUUL Virginia Tobacco closely match those previously reported in similar studies in US smokers [50, 58]. Secondly, while our studies included a period in which study subjects were allowed to use the study products prior to their nicotine pharmacokinetic and subjective effects assessments, this period was short. It has been noted that nicotine delivery from ENDS may change over time as users become acclimatised to the devices [36, 59, 60], and therefore, our findings may not reflect nicotine delivery in an acclimatised BIDI® Stick ENDS user. Thirdly, the study was of an open-label design, due primarily to the difficulty in blinding the subjects to the different study products (BIDI® Stick ENDS, JUUL ENDS, and UB cigarettes) which were all very different in format. It was also not possible to blind the subjects to the ENDS flavours. Finally, the study sample size was potentially not sufficient to identify statistically significant differences in the subjective effects measures.

Conclusions

In summary, nicotine pharmacokinetic assessments showed that the BIDI® Stick ENDS delivered nicotine to users in a manner comparable to their UB combustible cigarette, while also inducing comparable subjective effects including satisfaction and relief. These findings support the BIDI® Stick ENDS as a satisfying alternative for current smokers and may support their transitioning away from harmful cigarette smoking.

Availability of data and materials

The datasets analysed during the study are available from the corresponding author on reasonable request.

Abbreviations

AE:

Adverse event

AUC:

Area under the plasma nicotine concentration–time curve

CI:

Confidence interval

Cmax :

Maximum plasma nicotine concentration

ECG:

Electrocardiogram

eCO:

Exhaled carbon monoxide

ENDS:

Electronic nicotine delivery systems

FTCD:

Fagerstrom Test for Cigarette Dependence

GCP:

Good clinical practice

HPLC:

High-performance liquid chromatography

K2EDTA:

Dipotassium ethylenediaminetetraacetic acid

LLOQ:

Lower limit of quantification

PES:

Product evaluation scale

RPM:

Revolutions per minute

SD:

Standard deviation

Tmax :

Time of maximum plasma nicotine concentration

UB:

Usual brand (of combustible cigarette)

UK:

United Kingdom

ULOQ:

Upper limit of quantification

References

  1. World Health Organization. Tobacco; 2021. Available From: https://Www.Who.Int/News-Room/Fact-Sheets/Detail/Tobacco.

  2. Institute Of Medicine. Clearing the smoke - Assessing the Science Base for Tobacco Harm Reduction. Washington: The National Academies Press; 2001.

    Google Scholar 

  3. Perfetti T, Rodgman A. The complexity of tobacco and tobacco smoke. Beitr Zur Tab Int. 2011;24:17.

    Google Scholar 

  4. Stratton K, Shetty P, Wallace R, Bondurant S. Clearing the smoke: the science base for tobacco harm reduction - executive summary. Tob Control. 2001;10(2):189–95.

    Article  CAS  Google Scholar 

  5. Food and Drug Administration. Harmful and potentially harmful constituents in tobacco products and tobacco smoke; established list. Docket No. FDA–2012–N–0143. Federal Register, 2012.

  6. US Department of Health and Human Services. The Health Consequences of Smoking: 50 Years of Progress: a Report of the Surgeon General. Atlanta: Department of Health and Human Services, Centers for Disease Control and Prevention, National Center for Chronic Disease Prevention and Health Promotion, Office on Smoking and Health; 2014.

  7. Babb S, Malarcher A, Schauer G, Asman K, Jamal A. Quitting smoking among adults - United States, 2000–2015. MMWR Morb Mortal Wkly Rep. 2017;65(52):1457–64.

    Article  Google Scholar 

  8. Russell MA. Low-tar medium-nicotine cigarettes: a new approach to safer smoking. Br Med J. 1976;1(6023):1430–3.

    Article  Google Scholar 

  9. Public Health England. Evidence review of e-cigarettes and heated tobacco products 2018. A report commissioned by Public Health England. London: PHE Publications; 2018.

  10. Hatsukami DK, Carroll DM. Tobacco harm reduction: past history, current controversies and a proposed approach for the future. Prev Med. 2020;140: 106099.

    Article  Google Scholar 

  11. Royal College of Physicians. Nicotine without smoke. Tobacco harm reduction. A report by the tobacco advisory group of the Royal College of Physicians. London: Royal College of Physicians; 2016.

  12. Breland A, Soule E, Lopez A, Ramôa C, El-Hellani A, Eissenberg T. Electronic cigarettes: what are they and what do they do? Ann N Y Acad Sci. 2017;1394(1):5–30.

    Article  Google Scholar 

  13. Voos N, MI Goniewicz, Eissenberg T. What is the nicotine delivery profile of electronic cigarettes? Expert Opin Drug Deliv. 2019;16(11):1193–203.

    Article  CAS  Google Scholar 

  14. National Academies Of Sciences Engineering And Medicine. Public Health Consequences Of E-cigarettes. Washington: National Academies Press; 2018.

    Google Scholar 

  15. Margham J, Mcadam K, Forster M, Liu C, Wright C, Mariner D, et al. Chemical composition of aerosol from an e-cigarette: a quantitative comparison with cigarette smoke. Chem Res Toxicol. 2016;29(10):1662–78.

  16. Theron AJ, Feldman C, Richards GA, Tintinger GR, Anderson R. Electronic cigarettes: where to from here? J Thorac Dis. 2019;11(12):5572–85.

  17. Cohen G, Ni Goldenson, Bailey P, Chan S, Shiffman S. Changes in biomarkers of cigarette smoke exposure after 6 days of switching exclusively or partially to use of the JUUL system with two nicotine concentrations: a randomized controlled confinement study in adult smokers. Nicotine Tob Res. 2021;23(10):2153–61.

    Article  Google Scholar 

  18. Goniewicz ML, Smith DM, Edwards KC, Blount BC, Caldwell KL, Feng J, et al. comparison of nicotine and toxicant exposure in users of electronic cigarettes and combustible cigarettes. JAMA Netw Open. 2018;1(8):E185937.

    Article  Google Scholar 

  19. McEwan M, Gale N, Ebajemito JK, Camacho OM, Hardie G, Proctor CJ, et al. A randomized controlled study in healthy participants to explore the exposure continuum when smokers switch to a tobacco heating product or an e-cigarette relative to cessation. Toxicol Rep. 2021;8:994–1001.

    Article  CAS  Google Scholar 

  20. Morris P, MCdermott S, Chapman F, Verron T, Cahours X, Stevenson M, et al. Reductions In biomarkers of exposure to selected harmful and potentially harmful constituents following exclusive and partial switching from combustible cigarettes to myblu(™) electronic nicotine delivery systems (ENDS). Intern Emerg Med. 2021;26(10):021–02813.

    Google Scholar 

  21. Shahab L, Goniewicz ML, Blount BC, Brown J, Mcneill A, Alwis KU, et al. Nicotine, carcinogen, and toxin exposure in long-term e-cigarette and nicotine replacement therapy users: a cross-sectional study. Ann Intern Med. 2017;166(6):390–400.

    Article  Google Scholar 

  22. Smith DM, Shahab L, Blount BC, Gawron M, Kosminder L, Sobczak A, et al. Differences in exposure to nicotine, tobaccospecific nitrosamines, and volatile organic compounds among electronic cigarette users, tobacco smokers, and dual users from three countries. Toxics. 2020;8(4):88.

  23. Hartmann-Boyce J, Mcrobbie H, Butler AR, Lindson N, Bullen C, Begh R, et al. Electronic cigarettes for smoking cessation. Cochrane Database Syst Rev. 2021;9(9):Cd010216. 

    Article  PubMed  Google Scholar 

  24. Levy DT, Yuan Z, Luo Y, Abrams DB. The relationship Of E-cigarette use to cigarette quit attempts and cessation: insights from a large, nationally representative U.S. survey. Nicotine Tob Res. 2018;20(8):931–9.

    Article  Google Scholar 

  25. Berry KM, Reynolds LM, Collins JM, Siegel MB, Fetterman JL, Hamburg NM, et al. E-cigarette initiation and associated changes in smoking cessation and reduction: the population assessment of tobacco and health study, 2013–2015. Tob Control. 2019;28(1):42–9.

  26. Goldenson NI, Fearon IM, Buchhalter AR, Henningfield JE. An open-label, randomized, controlled, crossover study to assess nicotine pharmacokinetics and subjective effects of the JUUL system with three nicotine concentrations relative to combustible cigarettes in adult smokers. Nicotine Tob Res. 2021;23(6):947–55.

    Article  Google Scholar 

  27. Hajek P, Pittaccio K, Pesola F, Myers Smith K, Phillips-Waller A, Przulj D. Nicotine delivery and users’ reactions to JUUL compared with cigarettes and other e-cigarette products. Addiction. 2020;115(6):1141–8.

    Article  Google Scholar 

  28. Phillips-Waller A, Przulj D, Smith K, Pesola F, Hajek P. Cigarettes and other e-cigarette products. Psychopharmacology (Berl). 2021;238(3):825–31.

  29. Gottlieb S, Zeller M. A nicotine-focused framework for public health. N Engl J Med. 2017;377(12):1111–4.

    Article  Google Scholar 

  30. Hansson A, Rasmussen T, Kraiczi H. Single-dose and multiple-dose pharmacokinetics of nicotine 6 mg gum. Nicotine Tob Res. 2017;19(4):477–83.

  31. Hansson A, Rasmussen T, Perfekt R, Hall E, Kraiczi H. Effect of nicotine 6 mg gum on urges to smoke, a randomized clinical trial. BMC Pharmacol Toxicol. 2019;20(1):69.

    Article  CAS  Google Scholar 

  32. Lindson N, Chepkin SC, Ye W, Fanshawe TR, Bullen C, Hartmann-Boyce J. Different doses, durations and modes of delivery of nicotine replacement therapy for smoking cessation. Cochrane Database Syst Rev. 2019;4(4):Cd013308.

    PubMed  Google Scholar 

  33. Tobacco Use and Dependence Guideline Panel. Tobacco use and dependence guideline panel. Treating tobacco use and dependence: 2008 Update. Rockville, MD; 2008. Available From: https://Www.Ncbi.Nlm.Nih.Gov/Books/Nbk63952.

  34. Voos N, Kaiser L, Mahoney MC, Bradizza CM, Kozlowski LT, Benowitz NL, et al. Randomized within-subject trial to evaluate smokers’ initial perceptions, subjective effects and nicotine delivery across six vaporized nicotine products. Addiction. 2019;114(7):1236–48.

    Article  Google Scholar 

  35. Cobb CO, Foulds J, Yen MS, Veldheer S, Lopez AA, Yingst JM, et al. Effect of an electronic nicotine delivery system with 0, 8, or 36 mg/ml liquid nicotine versus a cigarette substitute on tobacco-related toxicant exposure: a four-arm, parallel-group, randomised. Control Trial Lancet Respir Med. 2021;9(8):840–50.

    Article  CAS  PubMed  Google Scholar 

  36. Hiler M, Breland A, Spindle T, Maloney S, Lipato T, Karaoghlanian N, et al. Electronic cigarette user plasma nicotine concentration, puff topography, heart rate, and subjective effects: influence of liquid nicotine concentration and user experience. Exp Clin Psychopharmacol. 2017;25(5):380–92.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  37. Fearon IM, Eldridge AC, Gale N, McEwan M, Stiles MF, Round EK. Nicotine pharmacokinetics of electronic cigarettes: a review of the literature. Regul Toxicol Pharmacol. 2018;100:25–34.

    Article  CAS  Google Scholar 

  38. Jacobson K, Martinez J, Larroque S, Jones IW, Paschke T. Nicotine pharmacokinetics of electronic cigarettes: a pooled data analysis from the literature. Toxicol Rep. 2021;8:84–95.

    Article  CAS  Google Scholar 

  39. Nides MA, Leischow SJ, Bhatter M, Simmons M. Nicotine blood levels and short-term smoking reduction with an electronic nicotine delivery system. Am J Health Behav. 2014;38(2):265–74. 

    Article  PubMed  Google Scholar 

  40. Fagerström K. Determinants of tobacco use and renaming the FTND to the Fagerström Test for Cigarette Dependence. Nicotine Tob Res. 2012;14(1):75–8.

    Article  Google Scholar 

  41. Yingst JM, Foulds J, Veldheer S, Hrabovsky S, Trushin N, Eissenberg TT, et al. Nicotine absorption during electronic cigarette use among regular users. PLoS One. 2019;14(7):E0220300.

    Article  CAS  Google Scholar 

  42. Bullen C, Mcrobbie H, Thornley S, Glover M, Lin R, Laugesen M. Effect of an electronic nicotine delivery device (e-cigarette) on desire to smoke and withdrawal, user preferences and nicotine delivery: randomised cross-over trial. Tob Control. 2010;19(2):98–103.

    Article  CAS  Google Scholar 

  43. Hatsukami DK, Zhang Y, O’Connor RJ, Severson HH. Subjective responses to oral tobacco products: scale validation. Nicotine Tob Res. 2013;15(7):1259.

  44. Ramôa CP, Hiler MM, Spindle TR, Lopez AA, Karaoghlanian N, Lipato T, et al. Electronic cigarette nicotine delivery can exceed that of combustible cigarettes: a preliminary report. Tob Control. 2016;25(E1):E6-9.

    Article  Google Scholar 

  45. Food and Drug Administration. Technical Project Lead review of IQOS. Silver Spring, MD, 2019. Available From: https://Www.Fda.Gov/Media/124247/Download.

  46. Do EK, O’connor K, Perks SN, Soule EK, Eissenberg T. E-cigarette device and liquid characteristics and e-cigarette dependence: a pilot study of pod-based and disposable e-cigarette users. Addict Behav. 2021;124(1):107117.

    PubMed  Google Scholar 

  47. Liu G, Wasserman E, Kong L, Foulds J. A comparison of nicotine dependence among exclusive E-cigarette and cigarette users in the path study. Prev Med. 2017;104:86–91.

    Article  Google Scholar 

  48. Shiffman S, Goldenson NI, Hatcher C, Augustson EM. Changes in dependence as smokers switch from cigarettes to JUUL in two nicotine concentrations. Am J Health Behav. 2021;45(3):563–75.

    Article  Google Scholar 

  49. Voos N, Smith D, Kaiser L, Mahoney MC, Bradizza CM, Kozlowski LT, et al. Effect of e-cigarette flavors on nicotine delivery and puffing topography: results from a randomized clinical trial of daily smokers. Psychopharmacology (Berl). 2020;237(2):491–502.

    Article  CAS  Google Scholar 

  50. Goldenson NI, Buchhalter AR, Augustson EM, Rubinstein ML, Henningfield JE. Abuse liability assessment of the JUUL system in four flavors relative to combustible cigarette, nicotine gum and a comparator electronic nicotine delivery system among adult smokers. Drug Alcohol Depend. 2020;217:108395.

    Article  Google Scholar 

  51. St Helen G, Dempsey DA, Havel CM, Jacob P, Benowitz NL. Impact of e-liquid flavors on nicotine intake and pharmacology of e-cigarettes. Drug Alcohol Depend. 2017;178:391–8.

    Article  CAS  Google Scholar 

  52. Stiles MF, Campbell LR, Graff DW, Jones BA, Fant RV, Henningfield JE. Pharmacodynamic and pharmacokinetic assessment of electronic cigarettes, combustible cigarettes, and nicotine gum: implications for abuse liability. Psychopharmacology. 2017;234(17):2643–55.

  53. Stiles MF, Campbell LR, Jin T, Graff DW, Fant RV, Henningfield JE. Assessment of the abuse liability of three menthol Vuse Solo electronic cigarettes relative to combustible cigarettes and nicotine gum. Psychopharmacology (Berl). 2018;235(7):2077–86.

    Article  CAS  Google Scholar 

  54. Abrams DB, Glasser AM, Villanti AC, Pearson JL, Rose S, Niaura RS. Managing nicotine without smoke to save lives now: evidence for harm minimization. Prev Med. 2018;117:88–97.

    Article  Google Scholar 

  55. Tucker MR, Laugesen M, Bullen C, Grace RC. Predicting short-term uptake of electronic cigarettes: effects of nicotine, subjective effects, and simulated demand. Nicotine Tobacco Res. 2018;20(10):1265–71.

    Article  CAS  Google Scholar 

  56. Higgins ST, Redner R, Arger CA, Kurti AN, Priest JS, Bunn JY. Use of higher-nicotine/tar-yield (regular full-flavor) cigarettes is associated with nicotine dependence and smoking during pregnancy among U.S. women. Prev Med. 2017;104:57–62.

    Article  Google Scholar 

  57. Kuiper N, Coats EM, Crawford TN, Gammon DG, Loomis B, Watson CH, et al. Trends in manufacturer-reported nicotine yields in cigarettes sold in the United States, 2013–2016. Prev Chronic Dis. 2020;17:E148.

    Article  Google Scholar 

  58. Goldenson NI, Buchhalter AR, Augustson EM, Rubinstein ML, Van Hoof D, Henningfield JE. Abuse liability assessment of the JUUL system in two nicotine concentrations compared to combustible cigarette, nicotine gum and comparator electronic nicotine delivery system. Drug Alcohol Depend. 2020;217:108441.

    Article  CAS  Google Scholar 

  59. Farsalinos KE, Spyrou A, Stefopoulos C, Tsimopoulou K, Kourkoveli P, Tsiapras D, et al. Nicotine absorption from electronic cigarette use: comparison between experienced consumers (vapers) and naïve users (smokers). Sci Rep. 2015;5:11269.

    Article  CAS  Google Scholar 

  60. Hajek P, Goniewicz ML, Phillips A, Myers Smith K, West O, Mcrobbie H. Nicotine intake from electronic cigarettes on initial use and after 4 weeks of regular use. Nicotine Tob Res. 2015;17(2):175–9.

    Article  CAS  Google Scholar 

Download references

Acknowledgements

The authors gratefully acknowledge the support of MTZ Clinical Research Sp. Z.o.o. (Warsaw, Poland) who conducted the study. The authors also wish to thank Azim Chowdhury and Neelam Gill (Keller and Heckman LLP, Washington DC, USA) who contributed to the execution of the study.

Funding

This study was sponsored by BIDI Vapor, LLC. This sponsor company had no involvement in the design or execution of the study other than to provide BIDI® Stick and JUUL ENDS and further had no involvement in either the analysis or the reporting of study data.

Author information

Authors and Affiliations

Authors

Contributions

IF designed the study, facilitated study conduct at MTZ, wrote the manuscript and interpreted the study findings. KG and WM contributed to both study conduct and manuscript writing. RGNS performed all statistical analyses presented in the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Ian M. Fearon.

Ethics declarations

Ethics approval and consent to participate

Ethics approval was received from the Ethics Committee of the District Medical Board in Warsaw (Resolution 15/21, 29 April 2021). All subjects provided written informed consent on an ethics committee-approved consent form before any study procedures were undertaken.

Consent for publication

No individual person’s data are reported in this paper.

Competing interests

IMF is an independent consultant contracted to ENDS and tobacco product manufacturers to provide scientific and regulatory support for clinical and behavioural studies. RGNS is an independent consultant who provides statistical support to ENDS manufacturers. KG is an employee of, and WM is the President of, McKinney Regulatory Science Advisors, LLC who are contracted to provide scientific and regulatory support to ENDS and tobacco product manufacturers.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Additional file 1:

Fig. S1. Image of the BIDI® Stick ENDS. Table S1. Demographic details for study subjects. aFagerström Test for Cigarette Dependence (FTCD) score at screening. bSelf-reported daily cigarette consumption at screening. Abbreviations: BMI, body mass index; min, minimum; max, maximum. Table S2. Mass loss from BIDI® Stick and JUUL ENDS during controlled and ad libitum use sessions. Data are presented in grams (g). Abbreviations: Min, minimum; max, maximum; VT, Virginia Tobacco. Table S3. Levels of Harmful and Potentially Harmful Constituents (HPHCs) in BIDI® Stick ENDS aerosol and 3R4F reference cigarette smoke. Data are per puff levels collected under International Organisation for Standardisation (ISO) conditions (55 ml puff volume, 2 second puff duration, 30 second interpuff interval) by a contract laboratory accredited under ISO 17025. Abbreviations: NA, not analysed; BDL, below detectable levels; NNK, Methyl[4-oxo-4-(pyridin-3-yl)butyl]nitrous amide; NNN, 3-[(2S)-1-Nitrosopyrrolidin-2-yl]pyridine.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Fearon, I.M., Gilligan, K., Seltzer, R.G.N. et al. A randomised, crossover, clinical study to assess nicotine pharmacokinetics and subjective effects of the BIDI® stick ENDS compared with combustible cigarettes and a comparator ENDS in adult smokers. Harm Reduct J 19, 57 (2022). https://doi.org/10.1186/s12954-022-00638-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12954-022-00638-0

Keywords